Tel: +86-571-6451 0919

Home > Portable cold/heat compress machine
Portable cold/heat compress machine

Portable cold compress machine

This product is a set of portable cold compress system, which is mainly composed of a refrigeration 280W Mini chiller, a portable ice bag, a power adapter / battery. By compressing the chiller system, the cold water which adapts to the temperature is entered into the circulation of the ice bag to achieve the effect of quick cooling, swelling and analgesia.

This product is used for various parts of the body that need to be used to cool the body, including medical rescue, special operations, firefighters, sports competitions, etc..


1. Features

①Small size and light weight:
This is a evaporation-compression refrigeration system,installed HZSS micro heat exchanger, and it is the most small one and lightest one when compare with similar product.
②High electric efficiency:
The refrigeration efficiency of the small micro refrigeration system is about 2, which is 5 times of the semiconductor refrigeration efficiency, and is far higher than other refrigeration and cooling methods.
③Easy operation:
The liquid connection and electrical connection of the product are both plugged by the quick connector.
④High temperature control accuracy:
The temperature can be manually set on the touch screen, and the product can achieve the temperature control accuracy of 1 degrees centigrade.
⑤High reliability and safety:
product development through a series of reliability and safety testing. The factory production of each product must go through the corresponding type test (vibration, pressure, high and low temperature environment, weather resistance, oil return, condensation, protection, liquid pump / fan components such as reliability, performance, electrical safety etc).

⑥Good environmental adoptability:
(1)Adapt to mobile sloshing environment (transportation, people carry).
(2)Adapt to 0.5 ~ 1 atmospheric pressure (high altitude) working environment.
(3)According to the requirements, it have the corresponding level of waterproof and dustproof function, electromagnetic compatibility, medical device certification.

⑦Add pressure treat:
The liquid pressure can be adjusted, and it can also supplly pulsating pressure when cold compressing.

2.Product structure and parameters


2.1 Naming rules


2.2 Product configuration

NO.Component typeComponent nameComponent description
1HostCompressorMiniature DC variable frequency compressor
2EvaporatorMicro-channel heat exchanger
3CondenserParallel flow micro-channel heat exchanger
4CryogenR134a Cryogen
5Display panelTouch panel
6Cold compress tabletMaterialMedical TPU material
7Water interfaceMatching quick joint
8HousingShellAluminum alloy shell,Surface anodic oxidation treatment
9Power supplyThe power adapterMedical type

2.3 Host structure


2.4 Host dimension


2.5 Parameters

Host parameters
Nominal refrigerating capacityW280
Nominal powerW150
Main input voltageVDC20~26
Host rated voltageVDC 24
Host rated currentA6.25
Host maximum currentA12
Range of output water temperature°C5~42
Volume of water tankL1.6
Temperature control modeTouch screen settings, host self-control
Maximum liquid supply pressurekPa60
Working environment temperature°C+10~+55
Storage environment temperature°C-30~+70
Host net weightkg5.5
Host noisedB(A)53
Circulating medium 100% pure water or distilled water
Appearance material■ABS / ■White
Note: Nominal working condition: The ambient temperature is 30 degrees centigrade. The liquid temperature is 10 degrees centigrade.
Power adapter parameters
InputVoltage range80~246VAC
Frequency range47~63Hz
Alternating current4A/115VAC 2A/230VAC
Surge current120A/230VAC
Contact leakage current<100μA/264VAC
OutputDC voltage24V
Rated current9.2A
Rated power221W
Current range0~9.2A
Ripple and Noise180mVp-p
Voltage accuracy±3%
ProtectionOverloadThe rated input power is 105% to 135%
OvervoltageThe rated output voltage is 105% to 13.5%
EnvironmentWorking temperature-30~+70°C
Working humidity20~90%RH,Non-condensing
Storage temperature-40~+85°C
Storage humidity10~95%RH
Electromagnetic compatibilityEMC emissionAccord with EN55011(CLSPR11)class B
EMC immunityAccord with grade A medical standard
ConnectorOutput plugKPPX-4P

3.Product performance

3.1Working range


Note: The host will alarm for a long time beyond  the operating range

3.2 Cooling capacity


3.3 Cold compress plate cooling time


4.Fault code

F1Compressor overload/condenser fouling F26Environmental temperature sensor fault
F2Compressor self-protectionF27Liquid temperature sensor fault
F3Compressor communication failure F28Fault of inlet temperature sensor
F4High temperature protection of compressorF30Electric heating fault
F11Fan 1 broken line F31Cold compress too high temperature protection
F12Fan 2 broken lineF41Liquid or liquid flow is low
F14Fan 1 overloadF42Environmental temperature anomaly
F15Fan 2 overloadF43Anti-freezing protection
F21Disconnection of water pumpF44Overvoltage/under voltage of power supply
F22Pump overload / water filtration blockage  

Note:When some fault occurs, the host will continue to operate, but it will automatically take some recovery measures or alternative measures.

Please send your message to us